Home About Us MSDS PRODUCTS Contact Us Sample Request

JEFFCO 2200

Pigmented Chemically Resistant Epoxy System for Coatings and Secondary Containment

Back to Civil Engineering page

System SKU: 2200
System Category: Civil Engineering

DESCRIPTION:
Premium quality, 100% solids epoxy coatings system specially designed as an industrial self-leveling coating. Contains no solvents (zero VOC) or carcinogens and has minimal odor to assure low toxicity and ease of application. Jeffco 2200 also has excellent self-leveling ability and has great bonding ability to new or old concrete. 2200 has excellent chemical resistance is ideal for secondary containment areas or in areas of high concentrations of chemicals. 8 standard industrial colors available.

APPLICATIONS:
- Moisture tolerant concrete primer
- Chemical resistant flooring and topcoat
- Self-leveling slurry
- Containment coatings

CONDITIONS TO AVOID:
Do not apply to concrete less than 30 days old.
Do not apply to concrete with curing or sealing membranes.
Do not apply to base concrete at a temperature less than 50°F.

SURFACE PREPARATION: Concrete surfaces must be structurally sound and free from contaminants such as dust, oil or dirt. Surfaces must be shot blasted or mechanically abraded to achieve a minimum 5-mil profile. Coated surfaces must be mechanically cleaned and abraded with 60-80-mesh sandpaper and approved by the manufacturer before coating. A calcium chloride “dome” test is recommended and hydrostatic pressure must be <5psi before epoxy coatings application. Free-standing water must be removed.

Follow general surface preparation and application procedures specified in ACI 503.1-4.

MIXING: Thorough and complete mixing is critical, a Jiffy mixer is recommended. First mix each component separately. Proportion each component at the ratio of 2 parts A (resin) to 1 part B (hardener) by volume or, if using 1-gallon kits, pour all of Part B (hardener) into Part A (resin) and mix at 400-600 RPM for 3-5 minutes. In case of pigmented material, no stripes or color variation should be visible. Use an up and down motion, scraping the mixing container sides and bottom. Mix no more material than may be applied in 20 minutes.

PRIMING: Best results are obtained using Jeffco 1500 series H20 based epoxy primers first. 1500 should be applied at a rate of 250 - 300 sq.ft. per gallon. Please refer to 1500 series data sheets for more information on these systems. Jeffco 2200 may be applied as self-priming floor coating. Allow 2200 primer coat to become tacky before applying overlay or topcoat.

FLOOR COATINGS: 2200 is an excellent bonding, high strength, chemically resistant protective floor coating. It is a low viscosity, self-leveling, moister insensitive coating. Apply by squeegee, trowel, or roller to desired thickness. A minimum of 15 mils should be applied for best results. Aggregate may be broadcast for additional thickness or slip-resistant quality in coating. Back rolling with a spiked roller will help eliminate any surface defects.

SLURRIES: Mix 2200 parts “A” and “B” thoroughly first, then add 1 part by volume suitable slurry filler (such as “marble-white”) and mix until uniform. Apply the slurry by squeegee.

CONTAINMENT COATINGS: 2200 is perfectly suited for use as a chemically resistant containment coating. Apply a primer coat to surface at a rate of 5-7 mils (200 –250 sq. feet per gallon). Apply additional coats at a rate of 10-15 mils (100-150 sq. feet per gallon) until desired thickness is reached.

PROPERTIES OF 2200:
Solids by Volume 100%
Volatile Organic Content (VOC) 0lbs/gal
Application Temperature 55F minimum, 100F max
Maximum Re-coat Time @ 77 24 hours
Dry To Touch @ 77ºF 8 hours
Light Traffic @ 77ºF 14-16 hours
Full Cure @ 77ºF 7 Days

ADDITIONAL NOTES:  Complies with ACI Standard 503.1 - 4 and ASTM C-881-90 Type I, II, IV, V, VI and VII. Grade 1, Class B,C,D,E and F. Cures in presence of moisture and humidity. Resin non-crystallizing.

 
PROPERTIES OF sp2200 SYSTEM LIQUID PROPERTIES (77ºF): Minimum Maximum
Resin Viscosity (Part "A")
Hardener Viscosity (Part "B")
Mixed Viscosity
Mix Ratio , Part 2 :1 2 :1
Pot Life, minutes @ 77ºF 25 30
Weight Per Gallon, Resin Part “A” (lbs.)
Weight Per Gallon, Hardener Part “B” (lbs.)
Color, Resin
Color, Hardener

CURED PHYSICAL PROPERTIES OF NEAT RESIN:

NEAT RESIN CURED PROPERTIES OF sp2200 SYSTEM: Minimum Maximum
Shore D Hardness 81 81
Tensile Strength 7,000 8,000
Flexural Strength 13,000 13,800
Compressive Strength 10,000 11,000
HDT, ºF 132 132
Elongation 5.0 5.0

SUPPLIED AS PACKAGED KITS:
3 Gallon, 15 Gallon, 165 Gallon

Back to Civil Engineering page

The information contained herein is offered without charge for use by technically qualified personnel at their discretion and risk. All statements, technical information and recommendations contained herein are based on test and data which we believe to be reliable, but the accuracy or completeness thereof is not guaranteed and no warranty of any kind is made with respect thereto. Always read, understand, and comply with hazard warnings described in the products' Material Safety Data Sheet(s) before use.
Home About Us MSDS PRODUCTS Contact Us Sample Request